ACOM Amplifier Support

Fault codes, diagnostics, and service reference for ACOM linear amplifiers

This reference is compiled from forums, user feedback, social media reports, and service documentation. Errors are possible — always verify against your amplifier's official user manual. Never attempt service unless you are a qualified technician.

Common support information covering ACOM 1000, 1200S, 1500, and 2000A amplifiers. Always disconnect mains power and wait 30 minutes before opening any ACOM amplifier — high voltages up to 3000V are LETHAL.

ACOM 1500 Auto-Protection Signatures

The ACOM 1500 stores the 7 most recent auto-protection trip signatures in nonvolatile memory. Each signature is a pair of screens (nA / nB) with 36 symbols total. Read them via OFF LINE mode (press OPER button).

First Group Decode (nA, first 6 symbols)

PositionValueMeaning
11A-7ATrip sequence number (1 = latest)
2-4PN0POWER-ON tests before HV
PN2 = POWER-ON after HV + 1s
2-4SB0STANDBY during warm-up
SB2 = STANDBY after warm-up
2-4PR0Entering OPERATE
PR2 = During OPERATE
2-4TR0/2Antenna relay Rx→Tx / Tx→Rx
TR4 = during Tx • TR6 = during Rx
61-9, B-FTrigger parameter (see below)

Trigger Parameter Legend

CodeSignalDescription
1pfwdPeak forward power (analogue)
2rflReflected power (analogue)
3inpInput / drive power (analogue)
4paavPeak anode alternate voltage (analogue)
5g2cScreen grid current (analogue)
6ipmPlate current (analogue)
7hvmHigh voltage (analogue)
8tempExhaust air temperature (analogue)
9g1c*Drive power present on control grid
BORCOutput relay closed (logic)
CARCFRF arc fault (logic)
DG1CControl grid current too high (logic)
EPSE+24V supply error (logic)
FLAIRLow airflow (logic)
Example: 1ATR4B = latest trip (1A) during Tx OPERATE (TR4), output relay closed signal failing (B).

Protection Levels

LevelNameEffectAction
1stWARNINGMessage only, TX continuesMonitor and reduce drive
2ndSOFT FAULTTrips to STANDBYCorrect conditions (reduce drive, fix SWR)
3rdAUTO PROTECTIONTrips to OFF LINERead signature, contact dealer
The 6dB input attenuator is inserted automatically ~1s after a bad tuning is detected above 20W drive. It resets on PTT release.

ACOM 1000 & 2000A Fault Codes

These models display fault codes on the front panel VFD. Common codes:

DisplayMeaningLikely Cause
GRIDExcessive grid currentOverdrive, bad tuning, tube aging
HVHigh voltage faultPSU issue, rectifier failure, filter cap aging
TEMPOver-temperatureFan failure, blocked air filter, extended high-duty TX
SWRHigh antenna SWRAntenna or feedline problem
ARCRF arc detectedDamage in tank circuit or antenna system
PWROverdrive / excessive powerReduce transceiver drive level
bAttBackup battery lowReplace BR1225 (2000A) or CR2032 (1000)

Common Failure Modes

Tube Failures (1000, 1500, 2000A)

HV Filter Capacitor Aging (1000, 1500, 2000A)

Vacuum Relay K1 (all models)

LDMOS Failure (1200S)

Fan Failure (all models)

Backup Battery (1000, 2000A)

Fuse Reference

Always disconnect mains and wait 30 minutes before accessing internal fuses.

ModelLocationTypeRatingSize
1200SRear panel (mains)Fast-acting10A/250V (200-240V)
16A/250V (100-120V)
5x20mm
Internal (PSU)Fast-acting2x 6.3A/250V5x20mm
1500Rear panel (mains) x2Fast-acting16A/250V (200-240V)
20A/250V (100-120V)
6.3x32mm
Internal MAINS PCBTime-lag0.2A/250V5x20mm
Internal MAINS PCB x2Time-lag2A/250V5x20mm
1000Rear panel (mains)Fast-acting10A/250V (200-240V)
16A/250V (100-120V)
5x20mm
InternalTime-lagAs per model5x20mm
2000ARear panel (mains)Fast-acting10A/250V (200-240V)
16A/250V (100-120V)
5x20mm
Internal HVTime-lagAs per model5x20mm

Bias Adjustment

Bias adjustment requires the amplifier open and powered — LETHAL VOLTAGES PRESENT. Only qualified service technicians should perform this.

ACOM 1000 & 2000A

ACOM 1500

ACOM 1200S

Model Comparison

Parameter1200S150010002000A
RF DeviceBLF188XR LDMOS4CX1000A tetrode4CX800A tetrode2x 4CX800A tetrode
Output Power1200W1500W PEP1000W1500-2000W
PSU TypeSwitched-modeLinear HV + uA723 screen regLinear HVLinear HV 3.5kVA
DisplayLCD + encoderOLED (VFD older)VFDVFD + RCU TFT
CPUProprietary MCU80C552-family80C55280C31 + Z86E04
BandswitchRelay matrixS1A-S1C manualS1A-S1C manualStepping motors M3-M5
Frequency1.8-54 MHz1.8-54 MHz1.8-54 MHz1.8-24.5 MHz (+28 mod)
Backup BatteryCR2032NVRAM (no battery)CR2032BR1225-1HC

Support Contacts

RegionContactDetails
WorldwideACOM Ltd. (Bulgaria)www.acom-bg.com • support@acom-bg.com
USA/CanadaDX Engineeringwww.dxengineering.com • ACOM spare parts stocked
UKML&S / Martin Lynch & Sonswww.hamradio.co.uk
EuropeAuthorised dealersCheck www.acom-bg.com for local dealer list
PartsACOM Spare Partsacom-bg.com/support/spare-parts
ACOM Bulgaria stocks spare parts for models up to 20+ years old. Tubes and vacuum relays are also available from RF Parts Co. and DX Engineering.